Metal Can Sealing Machine Parts and Function

This equipment is an 8-roller metal can sealing machine. Divided into 1 to 4 courses. 2 rollers per track. When you need to seal 7 layers, all 8 rollers are used. When it is necessary to seal 5 layers, the two rollers controlled by the top cam can be adjusted and used. The sealing of the can body and the can lid has to be rolled several times by the roller. The position of the sealing roller should be adjusted when sealing the can, and the adjustment bolts of the plane support on the tray can be adjusted according to the diameter of the sealing can (see Figure 12). Just loosen the locking bolt first, and then loosen the nut on the adjusting bolt, then the adjustment can be carried out. Twist the adjusting bolt to adjust the position of the sealing roller to any position within the allowable use range. After adjustment, it can be tightened again, and the adjustment is very convenient. For specific operations, first turn the rollers 2, 3, and 4 away, and adjust 1 roller. Note that the radial adjustment dimensions of 1 track and 2 rollers should be the same until the product is properly sealed. Sign to exit. Use the same method to adjust the remaining rollers. After adjustment, restore the position of each roller and try sealing again.

Adjustment of tank height:
1; The whole head part of the metal can sealing machine can move up and down. Note: Just loosen the two locking mechanisms on the upper side of the head, and then press the head up and down adjustment keys to the position you need. After adjustment, reset the locking mechanism. Must be reset. Otherwise, the machine cannot be started.
2: The holding mold should also be adjusted according to the height of the can body. As long as the diameter of the can lid is the same and the height of the can is different, the support rod can be moved up and down as long as the bolts of the clamping block on the can holding mold are loosened. The upper tank mold can be adjusted arbitrarily within the allowable range. Of course, if the tank diameter is different, then the holding tank mold must be changed.

Adjustment of positioning claw:
The can body positioning claw is installed on the conveying rack under the sub-lid base to accurately hold the can position. The holding mold must first determine the sealing position: hold a can body with the lid placed under the pressure head with the holding mold, and align it with the pressure head. After determining this position, fix the sensor switch next to the moving skateboard. Then move the tank holding mold to the left to a suitable position, that is, the holding tank position, and then adjust the position of the positioning claw and move the sensor switch at the other end of the sliding plate. All fixed.

The tension of the belt.
On the top of the metal can sealing machine, remove the belt pulley cover, and there is an adjustment bolt on the bottom plate where the motor is installed. Just loosen the fastening bolt on the bottom plate to adjust.